Agilent N9340BHandheld Spectrum Analyzer (HSA)3 GHz Technical OverviewField testing just got easier

Seite 2 - Front panel

10Spectrum emission mask (SEM)The new N9340B adds Spectrum Emission Mask (SEM) as a standard feature. SEMis a mask for out-of-channel emissions measur

Seite 3 - N9340B-XDM

11The detailed metrics offer you the complete understanding of the AM.The detailed metrics offer you the complete understanding of the FM.AM/FM modula

Seite 4 - N9340B applications for

12ASK/FSK modulation analysis (Option DMA)Optional ASK/FSK modulation analysis is now available. Amplitude Shift Keying (ASK) is used in RFID and opti

Seite 5

13High accuracy power measurementThe N9340B now supports high-accuracy, USB plug-and-play power measure-ments as standard when connected to an Agilent

Seite 6

14The field strength measurement automatically takes into the account of the antenna factor. The antenna table is definable by the standard N9340B PC

Seite 7

15Channel tableFor the users who prefer to tune the spectrum analyzer according to channel numbers rather than center frequency, you will find the new

Seite 8 - Occupied bandwidth (OBW)

16See traces clearly indoors and outdoors As with all the newest Agilent portable field equipment, operating under chal-lenging bright sunlight or ot

Seite 9 - Channel power

17N9340B supports remote control via SCPI over USB and LAN.Modern USB and LAN connectivity Remote control N9340B via SCPI over USB/LAN is now availabl

Seite 10 - Spectrum emission mask (SEM)

18SpecificationsSpecifications apply under the following conditions:• After a warm-up time of 30 minutes, and at least two hours of operation or stor

Seite 11

19Specifications (continued)Amplitude Supplemental informationMeasurement rangeDisplayed average noise level (DANL) to +20 dBmInput attenuator range 0

Seite 12

2Front panel1. 6.5 TFT display2. Light sensor3. Speaker4. Soft keys5. Back-lit keys6. Power on/off7. Function keys8. PresetTop panel9. RF INP

Seite 13

20Specifications (continued)Amplitude (continued) Supplemental informationRF Input VSWR (at tuned frequency)Attenuator setting 0 dB < 1.8 : 1 10 MH

Seite 14 - Field strength measurement

21General Supplemental informationDisplayResolution 640 x 480 pixelsSize and type 6.5 inch (170 mm) TFT color displayInternal memoryUser memory Able t

Seite 15 - Channel table

22Options Supplemental informationSpectrogram Monitoring (Option INM)3 display modes SpectrogramSpectrum traceCombination of spectrogram and spectrum

Seite 16

23Demodulation Supplemental informationFrequency range 10 MHz to 3 GHzCarrier power accuracy ± 2 dB± 1 dB TypicalCarrier power displayed resolution 0.

Seite 17 - Multi-language user interface

24Ordering informationModel number DescriptionN9340B Handheld spectrum analyzer 100 kHz to 3.0 GHzAccessories supplied as standard with each• Multi-l

Seite 18 - Specifications

www.agilent.comwww.agilent.com/find/hsawww.agilent.com/find/n9340bFor more information on Agilent Technologies’ products, applications or services, plea

Seite 19 - Specifications (continued)

3Know your spectrumRegardless of whether you are handling military communications, a Wireless Service Provider (WSP), or involved with spectrum manage

Seite 20

4N9340B is now equipped with powerful features to address field applications using a handheld spectrum analyzer. An analysis is identifying interferin

Seite 21

5The N9340B INM shows spectrogram and spectrum trace on the same screen.Extended spectrogrammonitoring (Option INM)Option INM extends the N9340B spect

Seite 22

6DSL measurements (Option XDM) xDSL (ADSL and VDSL) is widely used for broadband internet connections at homes and businesses. Service providers occas

Seite 23

7IBOC measurements (Option IBC) Option IBC equips the N9340B with in-band on-channel (IBOC) measurement capability through a dedicated measurement per

Seite 24 - Ordering information

8One-button measurementThe Agilent N9340B supports one-button measurements of occupied bandwidth, channel power and adjacent channel power ratio. This

Seite 25 - (BP-09-27-13)

9Channel powerUse channel power to measure both power and power spectral density in a user-specified channel bandwidth. One pair of vertical lines on