Agilent 16850 Series Portable Logic AnalyzersData SheetThe industry’s fastest timing capture with deep memory ― for fast digital system debug• 2.5 G
1016850 Series capture and decode of DDR3 Addr/Cmd linesCompliance test analysis of DDR3 Addr/Cmd line saved traceFigure 5. Multiple views for DDR2 an
11Deep memory capture with 2.5 GHz (400 ps resolution) timingFigure 6. Timing mode capture with 400 ps resolution and up to 128 M samples memory dept
12Standard data viewsWaveform Integrated display of data as digital waveforms, analog waveforms imported from an external oscilloscope, and/or as a ch
1316850 Series Instrument Characteristics (continued)16850 Series PC characteristicsOperating system Microsoft Windows® 7 Embedded (64-bit)Processor
14Peripheral interfacesDisplay One 15-pin XGA connector and one DVI connectorKeyboard PS/2Mouse PS/2 Serial 9-pin D-sub PCI card expansion slot 1
15Power16851A 100 to 240V ± 10 %, 50/60Hz, 400 W max16852A 100 to 240V ± 10 %, 50/60Hz, 400 W max16853A 100 to 240V ± 10 %, 50/60Hz, 400 W max16854A 1
16Ordering InformationEach 16850 Series portable logic analyzer comes with one USB keyboard, one USB mouse, accessory pouch, power cord and 3-year war
17Agilent product or option number Description Ordering informationE5864A Additional external hard drive (imaged with operating system and logic analy
www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of th
216850 Series Portable Logic Analyzer Selection GuideSpecifications and characteristics16851A 16852A 16853A 16854AChannels 34 68 102 136Maximum timing
3Industry’s Fastest Timing Capture with Deep Memory ― for Fast Digital System DebugFigure 1. With four models to choose from, and options to upgrade s
4Automate measurement setup and quickly gain diagnostic clues16850 Series logic analyzers make it easy for you to get up and running quickly by autom
516850 Series Logic Analyzer Specifications and Characteristics16851A 16852A 16853A 16854ANumber of channels 34 (1 clock + 1 clock qualifier)68 ( 1 c
6Trigger characteristics (conventional timing, transitional timing, and state sampling modes)Maximum trigger sequence speed (standard) (nom) 700 MHz (
7Seamless oscilloscope integration with View ScopeEasily make time-correlated measurements between Agilent logic analyzers and oscilloscopes. The time
8Acquisition and analysis tools provide rapid insight into your toughest debug problemsWhen you want to understand what your target is doing and why,
9The state analysis capabilities of the 16850 Series allow it to make measurements and analysis on DDR2 and DDR3 memories up to DDR2/3 1333 (667 MHz c
Kommentare zu diesen Handbüchern