Agilent Technologies E5864A Spezifikationen

Stöbern Sie online oder laden Sie Spezifikationen nach Multimeter Agilent Technologies E5864A herunter. Agilent Technologies E5864A Specifications [en] Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 18
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
Agilent 16850 Series
Portable Logic Analyzers
Data Sheet
The industry’s fastest timing capture with deep
memory ― for fast digital system debug
• 2.5 GHz timing capture with
up to 128 M sample memory
for finding elusive problems
quickly, even far from the
trigger point
• Up to 1.4 GHz trigger
sequencer speed for state
and timing capture
• Single-ended and differential
probing for the widest range
of supported technologies
Seitenansicht 0
1 2 3 4 5 6 ... 17 18

Inhaltsverzeichnis

Seite 1 - Portable Logic Analyzers

Agilent 16850 Series Portable Logic AnalyzersData SheetThe industry’s fastest timing capture with deep memory ― for fast digital system debug• 2.5 G

Seite 2 - 16851A 16852A 16853A 16854A

1016850 Series capture and decode of DDR3 Addr/Cmd linesCompliance test analysis of DDR3 Addr/Cmd line saved traceFigure 5. Multiple views for DDR2 an

Seite 3 - System Debug

11Deep memory capture with 2.5 GHz (400 ps resolution) timingFigure 6. Timing mode capture with 400 ps resolution and up to 128 M samples memory dept

Seite 4 - Automate measurement setup

12Standard data viewsWaveform Integrated display of data as digital waveforms, analog waveforms imported from an external oscilloscope, and/or as a ch

Seite 5 - (up to 128 M depth)

1316850 Series Instrument Characteristics (continued)16850 Series PC characteristicsOperating system Microsoft Windows® 7 Embedded (64-bit)Processor

Seite 6

14Peripheral interfacesDisplay One 15-pin XGA connector and one DVI connectorKeyboard PS/2Mouse PS/2 Serial 9-pin D-sub PCI card expansion slot 1

Seite 7 - Feature Benefit

15Power16851A 100 to 240V ± 10 %, 50/60Hz, 400 W max16852A 100 to 240V ± 10 %, 50/60Hz, 400 W max16853A 100 to 240V ± 10 %, 50/60Hz, 400 W max16854A 1

Seite 8

16Ordering InformationEach 16850 Series portable logic analyzer comes with one USB keyboard, one USB mouse, accessory pouch, power cord and 3-year war

Seite 9 - DDR2 memory DDR3 memory

17Agilent product or option number Description Ordering informationE5864A Additional external hard drive (imaged with operating system and logic analy

Seite 10 - (continued)

www.lxistandard.org LAN extensions for Instruments puts the power of Ethernet and the Web inside your test systems. Agilent is a founding member of th

Seite 11

216850 Series Portable Logic Analyzer Selection GuideSpecifications and characteristics16851A 16852A 16853A 16854AChannels 34 68 102 136Maximum timing

Seite 12 - Standard analysis tools

3Industry’s Fastest Timing Capture with Deep Memory ― for Fast Digital System DebugFigure 1. With four models to choose from, and options to upgrade s

Seite 13

4Automate measurement setup and quickly gain diagnostic clues16850 Series logic analyzers make it easy for you to get up and running quickly by autom

Seite 14 - 16850 Series Interfaces

516850 Series Logic Analyzer Specifications and Characteristics16851A 16852A 16853A 16854ANumber of channels 34 (1 clock + 1 clock qualifier)68 ( 1 c

Seite 15

6Trigger characteristics (conventional timing, transitional timing, and state sampling modes)Maximum trigger sequence speed (standard) (nom) 700 MHz (

Seite 16 - Ordering Information

7Seamless oscilloscope integration with View ScopeEasily make time-correlated measurements between Agilent logic analyzers and oscilloscopes. The time

Seite 17 - Related Literature

8Acquisition and analysis tools provide rapid insight into your toughest debug problemsWhen you want to understand what your target is doing and why,

Seite 18 - ISO 9001:2008

9The state analysis capabilities of the 16850 Series allow it to make measurements and analysis on DDR2 and DDR3 memories up to DDR2/3 1333 (667 MHz c

Kommentare zu diesen Handbüchern

Keine Kommentare