Agilent Technologies 8495 Wartungshandbuch

Stöbern Sie online oder laden Sie Wartungshandbuch nach Multimeter Agilent Technologies 8495 herunter. Agilent Technologies 8495 Service manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - Attenuators

Agilent TechnologiesAgilent 8495D/K AttenuatorsOperating and Service Manual

Seite 2

10 Agilent 8495D/K Attenuators Operating and Service Manual 1 IntroductionProduct OverviewThe Agilent 8495D and 8495K are 50- ohm, dc to 26.5 GHz, 0

Seite 3 - WEEE Compliance

Introduction 1Agilent 8495D/K Attenuators Operating and Service Manual 11Figure 1 8495K Programmable Four-Section Attenuator Schematic DiagramIn the 8

Seite 4 - Regulatory Markings

12 Agilent 8495D/K Attenuators Operating and Service Manual 1 IntroductionSupplied AccessoriesA solenoid drive cable is supplied with the 8495K. The

Seite 5 - Contacting Agilent

Introduction 1Agilent 8495D/K Attenuators Operating and Service Manual 13Solenoid Cable ConnectorsRefer also to Figure 2 on page 13.Figure 2 Solenoid

Seite 6

14 Agilent 8495D/K Attenuators Operating and Service Manual 1 IntroductionFigure 3 Typical Solenoid Coil Driver CircuitSolenoid cable connector jack

Seite 7 - Contents

Introduction 1Agilent 8495D/K Attenuators Operating and Service Manual 15SpecificationsFrequency Range and AttenuationAttenuation AccuracyMaximum Inse

Seite 8

16 Agilent 8495D/K Attenuators Operating and Service Manual 1 IntroductionAttenuation Repeatability±0.03 dB max to 18 GHz±0.05 dB max to 26.5 GHz(5

Seite 9 - Introduction

Introduction 1Agilent 8495D/K Attenuators Operating and Service Manual 17Maximum SWROperating Life5 million cycles per section.Table 6 Maximum SWRInst

Seite 10 - Product Overview

18 Agilent 8495D/K Attenuators Operating and Service Manual 1 IntroductionThis page is intentionally left blank.

Seite 11

19Agilent 8495D/K AttenuatorsOperating and Service ManualAgilent Technologies2Environmental Specifications & Physical DimensionsEnvironmental Spec

Seite 12 - Supplied Accessories

2 Agilent 8495D/K Attenuators Operating and Service ManualNotices© Agilent Technologies, Inc. 2011No part of this manual may be reproduced in any form

Seite 13 - Solenoid Cable Connectors

20 Agilent 8495D/K Attenuators Operating and Service Manual 2 Environmental Specifications & Physical DimensionsEnvironmental Specifications The

Seite 14 - 1 Introduction

Environmental Specifications & Physical Dimensions 2Agilent 8495D/K Attenuators Operating and Service Manual 21Physical DimensionsTable 8 shows th

Seite 15 - Specifications

22 Agilent 8495D/K Attenuators Operating and Service Manual 2 Environmental Specifications & Physical DimensionsFigure 4 Dimensions of Agilent 8

Seite 16 - RF Power Handling Capability

Environmental Specifications & Physical Dimensions 2Agilent 8495D/K Attenuators Operating and Service Manual 23Figure 5 Dimensions of Agilent 8495

Seite 17 - Operating Life

24 Agilent 8495D/K Attenuators Operating and Service Manual 2 Environmental Specifications & Physical DimensionsThis page is intentionally left

Seite 18

25Agilent 8495D/K AttenuatorsOperating and Service ManualAgilent Technologies3Operating GuidesInstallation 26Initial Inspection 26Mating Connectors 27

Seite 19 - Physical Dimensions

26 Agilent 8495D/K Attenuators Operating and Service Manual 3Operating GuidesInstallationInitial Inspection1 Inspect the shipping container for damage

Seite 20 - Environmental Specifications

Operating Guides 3Agilent 8495D/K Attenuators Operating and Service Manual 27Mating ConnectorsThe APC 3.5 connector is a 3.5- mm air line connector th

Seite 21

28 Agilent 8495D/K Attenuators Operating and Service Manual 3Operating GuidesOperating InstructionsOperating InformationEither RF connector may be use

Seite 22

Operating Guides 3Agilent 8495D/K Attenuators Operating and Service Manual 29Figure 6 Operator’s Check SetupProcedure1 Connect equipment as shown in F

Seite 23

Agilent 8495D/K Attenuators Operating and Service Manual 3CertificationAgilent Technologies certifies that this product met its published specificatio

Seite 24

30 Agilent 8495D/K Attenuators Operating and Service Manual 3Operating GuidesTable 9 Attenuator and SWR SettingsSWR Meter Range (dB)Attenuation Meter

Seite 25 - Operating Guides

Operating Guides 3Agilent 8495D/K Attenuators Operating and Service Manual 31Performance TestsThe Agilent 8495D/K Attenuators can be tested to the acc

Seite 26 - Installation

32 Agilent 8495D/K Attenuators Operating and Service Manual 3Operating GuidesThis page is intentionally left blank.

Seite 27 - Installation Instructions

4 Agilent 8495D/K Attenuators Operating and Service ManualRegulatory MarkingsThe CE mark is a registered trademark of the European Community. If it i

Seite 28 - Operating Instructions

Agilent 8495D/K Attenuators Operating and Service Manual 5Contacting Agilent For more information, please contact your nearest Agilent office.Or, go t

Seite 29 - Procedure

6 Agilent 8495D/K Attenuators Operating and Service ManualThis page is intentionally left blank.

Seite 30 - 3Operating Guides

Agilent 8495D/K Attenuators Operating and Service Manual 7Contents1 Introduction 9Product Overview 10Supplied Accessories 12Specifications 15Frequenc

Seite 31 - Service Instructions

8 Agilent 8495D/K Attenuators Operating and Service ManualThis page is intentionally left blank.

Seite 32

9Agilent 8495D/K AttenuatorsOperating and Service ManualAgilent Technologies1IntroductionProduct Overview 10Supplied Accessories 12Specifications 15Fr

Kommentare zu diesen Handbüchern

Keine Kommentare