Agilent TechnologiesAgilent E6630A Wireless Connectivity Test SetGetting Started GuideNotice: This document contains references to Agilent. Please no
Quick-Start 1Getting Started Guide 11The multiport adapter splits the downlink RF signal from the test set’s source into eight RF output paths. All ei
Troubleshooting 5Getting Started Guide 101Returning a test set for ServiceCalling Agilent Technologies Agilent Technologies has offices around the wor
102 Getting Started Guide5 TroubleshootingRead the Warranty The warranty for your test set is in the front of your Specifications Guide. Please read i
Troubleshooting 5Getting Started Guide 103Packaging the Test SetUse original packaging or comparable. It is best to pack the unit in the original fact
104 Getting Started Guide5 Troubleshooting
Getting Started Guide 105IndexSymbols.NET, 55Aadda network connection, 53a printer, 54Administrator logon, 44Adobe Acrobat Reader, 55Agilent dire
106 Getting Started GuideIndexMMicrosoft SQL Server Desktop Engine, 55Microsoft Visual J# .NET, 55Microsoft WindowsAutomatic Updates, 53Display set
IndexGetting Started Guide 107Windows 7operating system, 75Windows Classic Style, 54Windows firewall, 59Windows Remote Desktop, 77keycodes, 86opt
108 Getting Started GuideIndexThis information is subject to change without notice. © Keysight Technologies, 2014Published in USA, December 2014E6630-
12 Getting Started Guide1 Quick-StartInstrument SelectionOn the monitor or remote desktop view of the test set, each of the two instruments is represe
Quick-Start 1Getting Started Guide 13Initial InspectionInspect the shipping container and the cushioning material for signs of stress. Retain the ship
14 Getting Started Guide1 Quick-StartShipping problems?If the shipping materials are damaged or the contents of the container are incomplete:• Contact
Quick-Start 1Getting Started Guide 15Turning on the test set the first timeInitializing the test set using a USB mouse and external monitorDuring the
16 Getting Started Guide1 Quick-Start4 Launch Microsoft Setup Wizard• Highlight Microsoft Windows and press Enter to start the pre-installed operating
Quick-Start 1Getting Started Guide 17• This window appears and covers the LaunchXSA window. If you do not check the “Do not show this message again” c
18 Getting Started Guide1 Quick-Start8 Verify the installation a From the mouse right-click menu, select Utility, Virtual Front Panel. (All key-presse
Quick-Start 1Getting Started Guide 19The 2.4 GHz signal appears on the display.11 If an E6618A Multiport Adapter will be used, connect the E6618A hard
20 Getting Started Guide1 Quick-StartSource Level AccuracyTo ensure accurate power levels from the Vector Signal Generator, two adjustments need to be
Notices© Agilent Technologies, Inc. 2013-2014No part of this manual may be reproduced in any form or by any means (including electronic storage and re
Quick-Start 1Getting Started Guide 21OptionsThe options installed on the test set are listed on the System > Show > System display. Anti-Virus S
22 Getting Started Guide1 Quick-StartInstrument InformationPower requirementsThe only physical installation of your Agilent test set is a connection t
Quick-Start 1Getting Started Guide 23AC power cordThe test set is equipped with a three-wire power cord, in accordance with international safety stand
24 Getting Started Guide1 Quick-StartVentilation Instrument MaintenanceCleaning the instrumentCleaning the connectorsBattery InformationThe test set u
Quick-Start 1Getting Started Guide 25
26 Getting Started Guide1 Quick-StartProtecting against electrostatic dischargeElectrostatic discharge (ESD) can damage or destroy electronic componen
27Agilent E6630A Wireless Connectivity Test SetGetting Started GuideAgilent Technologies2Front Panel FeaturesThis section describes the following feat
28 Getting Started Guide2 Front Panel FeaturesFront-Panel Features The test set consists of instruments loaded in a PXI rack. There is a controller (l
Front Panel Features 2Getting Started Guide 29Each of the sub-instruments under the impact cover includes a Vector Signal Generator (M9381A) and a Vec
30 Getting Started Guide2 Front Panel FeaturesInput/Output Hardware InterfaceThe connectors which are exposed when the impact cover is in place are il
In This Guide…This guide contains the following information: 1 Quick-StartThis chapter explains how to initialize the test set and generate and vie
Front Panel Features 2Getting Started Guide 319 TRIG IN This BNC trigger port (for the right sub-instrument) accepts an external trigger input to the
32 Getting Started Guide2 Front Panel FeaturesController Hardware InterfaceThe controller is exposed even when the impact cover is in place. The conne
Front Panel Features 2Getting Started Guide 33LAN Connectors Gigabit Ethernet (GbE) LAN: two RJ-45 connectors with speed/link/active LED on the facepl
34 Getting Started Guide2 Front Panel FeaturesVirtual Front PanelThe E6630A model does not include physical front-panel keys. However, if you have a P
Front Panel Features 2Getting Started Guide 35On the VFP the keys labeled "Key 1" through "Key 7" function as the menu keys. Using
36 Getting Started Guide2 Front Panel FeaturesDisplay AnnotationsItemFunction Key# Description1 Measurement bar; shows general measurement settings an
Front Panel Features 2Getting Started Guide 376 Settings panel; displays system information that is not specific to any one application.• Input/Output
38 Getting Started Guide2 Front Panel FeaturesRear-Panel FeaturesItemDescription# Name1 Line power input The AC power connection. See the product spec
Front Panel Features 2Getting Started Guide 39Front and Rear Panel Symbols This symbol is used to indicate power ON (green LED). This symbol is us
40 Getting Started Guide2 Front Panel Features
Getting Started Guide 5Contents1 Quick-StartAbout the Test Set 10Instrument Selection 12Initial Inspection 13Table. Verifying the conte
41Agilent E6630A Wireless Connectivity Test SetGetting Started GuideAgilent Technologies3Test Set Operating SystemThis chapter describes the Microsoft
42 Getting Started Guide3 Test Set Operating SystemAgilent Software InstalledAgilent V9060A & V9077A softwareThe Agilent V9060A IQ Analyzer applic
Test Set Operating System 3Getting Started Guide 43Customer Installation of Software3rd party software verified by AgilentAgilent has verified that th
44 Getting Started Guide3 Test Set Operating SystemUser AccountsAdministrator loginThe Administrator account ships from the factory with the password
Test Set Operating System 3Getting Started Guide 45Customer creation of accountsYou can create additional user accounts and decide on the level of sec
46 Getting Started Guide3 Test Set Operating SystemAgilent Licensing OptionsAgilent test sets use three licensing types: Fixed Perpetual, Transportabl
Test Set Operating System 3Getting Started Guide 47Time-Limited LicensesTrial licensesTrial licenses are available so that you may try applications be
48 Getting Started Guide3 Test Set Operating SystemLicensing New Measurement Application Software - After Initial PurchaseAdditional measurement appli
Test Set Operating System 3Getting Started Guide 494 Verify installation a Cycle the power on the signal test set.b On the Virtual Front Panel press S
50 Getting Started Guide3 Test Set Operating SystemTransporting a License Between Test SetsTransportable licenses can be identified by the letters &qu
6 Getting Started GuideDisplay Annotations 36Rear-Panel Features 38Front and Rear Panel Symbols 393 Test Set Operating SystemAgilent So
Test Set Operating System 3Getting Started Guide 514 Start the License Manager on the Source Instrument• On the source instrument, press System, More,
52 Getting Started Guide3 Test Set Operating System8 Install License File in Target Instrumenta With the target instrument running, insert the USB fla
Test Set Operating System 3Getting Started Guide 53Windows ConfigurationThe Windows settings have been optimized for the best measurement performance.
54 Getting Started Guide3 Test Set Operating SystemSettings that must not be changedAvoid changing any settings in this section. Changes to the follow
Test Set Operating System 3Getting Started Guide 55In addition, DO NOT:• Add, delete, or modify hard-disk drive partitions.• Delete or modify Agilent
56 Getting Started Guide3 Test Set Operating SystemConfiguring PrintersPrinters are configured using the Microsoft Windows Control Panel. It is easily
Test Set Operating System 3Getting Started Guide 57Configuring LANHostnameThe Computer Name, or hostname, is pre-configured from the factory. It must
58 Getting Started Guide3 Test Set Operating SystemWindows SecurityMicrosoft recommends the following to ensure the test set Windows operating system
Test Set Operating System 3Getting Started Guide 59Windows FirewallThe test set is shipped with the Windows Firewall enabled.Windows Firewall Exceptio
60 Getting Started Guide3 Test Set Operating SystemVirus protectionThere is no antivirus software included with your test set. Antivirus application s
Getting Started Guide 7Disk defragmenting 62USB Connections 63Hard Drive Partitioning and Use 64Hard Drive Recovery Process 65Upda
Test Set Operating System 3Getting Started Guide 61Spyware protectionThere is no anti-spyware software installed on the test set. This should not be a
62 Getting Started Guide3 Test Set Operating SystemSystem MaintenanceBackupIt is recommended that you have a regular backup strategy. Your IT departme
Test Set Operating System 3Getting Started Guide 63USB ConnectionsAll of the USB ports are compatible with the USB 2.0 and 1.1 specification. The four
64 Getting Started Guide3 Test Set Operating SystemHard Drive Partitioning and UseThe drive is partitioned into 3 sections: C:, D: and E:•The C: parti
Test Set Operating System 3Getting Started Guide 65Hard Drive Recovery ProcessThe Agilent Recovery System can be used to repair errors on the test set
66 Getting Started Guide3 Test Set Operating SystemUsing the test set recovery systemStep Notes1 Make sure the test set is turned off.2 Turn on the te
Test Set Operating System 3Getting Started Guide 67Updating the softwareThe purpose of this update is to ensure that the E6630A’s software, its measur
68 Getting Started Guide3 Test Set Operating SystemUser account and log-inThe default user account is Instrument, which does not have the required per
Test Set Operating System 3Getting Started Guide 692 A window appears showing the extraction of the software installer. Click Install in the confirmat
70 Getting Started Guide3 Test Set Operating SystemSoftware updater window, showing uninstallation progress:While the old instrument software is being
8 Getting Started Guide
Test Set Operating System 3Getting Started Guide 71FPGA update warning window (may be displayed, if any FPGA updating occurs):CAUTION During FPGA prog
72 Getting Started Guide3 Test Set Operating SystemIt is possible a newer version of the instrument software is available on the web at http://www.agi
Test Set Operating System 3Getting Started Guide 73Configuring recovery prompt timingYou can configure the time at which the test set power-up process
74 Getting Started Guide3 Test Set Operating System
75Agilent E6630A Wireless Connectivity Test SetGetting Started GuideAgilent Technologies4Using Microsoft Windows Operating System“Navigating Windows W
76 Getting Started Guide4 Using Microsoft Windows Operating SystemNavigating Windows Without a MouseKey Presses ActionsEsc Exits/closes a Windows dial
Using Microsoft Windows Operating System 4Getting Started Guide 77Remote Desktop: Using the Sest Set RemotelyWindows Remote Desktop is recommended for
78 Getting Started Guide4 Using Microsoft Windows Operating System Basic setup for remote desktop operationSetting up the remote computerThe procedure
Using Microsoft Windows Operating System 4Getting Started Guide 79Remote computer running another version of Windows You can use any 32-bit version o
80 Getting Started Guide4 Using Microsoft Windows Operating System2 The computer name is displayed in the System window, under the heading “Computer n
9Agilent E6630A Wireless Connectivity Test SetGetting Started GuideAgilent Technologies1Quick-StartThis section explains how to initialize the test se
Using Microsoft Windows Operating System 4Getting Started Guide 81Running a Remote Desktop sessionInitializing a Remote Desktop sessionAfter setting u
82 Getting Started Guide4 Using Microsoft Windows Operating System• “Accessing menus for Remote Desktop operation" on page 85• “Keycode commands
Using Microsoft Windows Operating System 4Getting Started Guide 833 Click the Display tab.• Under Remote desktop size, you may select the size of the
84 Getting Started Guide4 Using Microsoft Windows Operating System5 Click the Experience tab. To Optimize the performance of the Remote Desktop sessio
Using Microsoft Windows Operating System 4Getting Started Guide 85Accessing menus for Remote Desktop operationUsing the mouse, right-click the applica
86 Getting Started Guide4 Using Microsoft Windows Operating SystemKeycode commands for Remote Desktop operationWhen using the test set in remote deskt
Using Microsoft Windows Operating System 4Getting Started Guide 87Cont Ctrl+Alt+CCtrl CtrlDecrease Audio Volume the Volume Control sliderDelDeleteDown
88 Getting Started Guide4 Using Microsoft Windows Operating SystemRight Arrow Right ArrowSaveCtrl+SSelect Space BarSingleCtrl+Alt+SSoftkey 1 Ctrl+Shif
Using Microsoft Windows Operating System 4Getting Started Guide 89Ending a Remote Desktop sessionThere are two ways to disconnect the remote computer
90 Getting Started Guide4 Using Microsoft Windows Operating SystemThe Virtual Front PanelThe Virtual Front Panel is a software equivalent of the front
10 Getting Started Guide1 Quick-StartAbout the Test SetThe E6630A Wireless Connectivity Test Set contains one or two transmit/receive instruments cont
Using Microsoft Windows Operating System 4Getting Started Guide 91Capturing/Printing Displays and WindowsYou need an external keyboard and mouse to us
92 Getting Started Guide4 Using Microsoft Windows Operating SystemWindows Shortcuts and Miscellaneous TasksThis section provides a list of Windows sho
Using Microsoft Windows Operating System 4Getting Started Guide 93Navigating an Application Menu without a Mouse or KeyboardThis example uses Microsof
94 Getting Started Guide4 Using Microsoft Windows Operating SystemIf a mouse is attached to the test set, and you move the mouse cursor to the bottom
Using Microsoft Windows Operating System 4Getting Started Guide 95Windows startup folderAll Windows systems include a special folder, called the Start
96 Getting Started Guide4 Using Microsoft Windows Operating System
97Agilent E6630A Wireless Connectivity Test SetGetting Started GuideAgilent Technologies5Troubleshooting “Check the Basics" on page 98“Problems w
98 Getting Started Guide5 TroubleshootingCheck the Basicso Is there power at the receptacle? o Is the test set turned on? Check to see if the green LE
Troubleshooting 5Getting Started Guide 99o If the previously performed alignments did not resolve the problem, press System, Alignments, Restore Align
100 Getting Started Guide5 TroubleshootingProblems with Microsoft Windows Operating SystemThe Microsoft Windows operating system settings have been op
Kommentare zu diesen Handbüchern